Secure Meters Sprint 350 User Manual

Sprint 350 is an enhanced metering solution for three-phase direct-connected installations. It is suitable for domestic. Secure Meters Limited. Sprint 200 family Modular Three Phase Smart Meter. Sprint 200 DLC Benefits ŸNo manual intervention required for data collection. Sprint 350 Three Phase kWh Meter Direct Connected The Sprint 350 advanced accumulation meter is an enhanced metering solution for three-phase direct-connected installations. It is suitable for domestic, industrial and commercial applications. Certificate of Approval NMI 14/2/84. Secure Products Distribution Utility service point - LV Sprint 350 Sprint 350 is a three-phase direct-connected energy meter with advanced revenue protection features, interoperable communications protocol, and support for reading in the absence of mains supply. I-Credit 300 meets the present day need of utilities for an accurate, reliable and cost effective electronic meter for single phase consumers. It provides an affordable solution in a dynamic market through comprehensive and advanced functionalities. I-Credit 300 features intelligent revenue protection facilities for.

If you are in Sri Lanka and you have got your self a net meter from CEB (Solar power), then its very likely that you have a Sprint 350 energy meter. Before we proceed any further, I like to say, this is the least intuitive electronic device I’ve ever seen.

I am trying to get live data from secure meter sprint 350 to my remote server data base. In meter there is a RJ11 port is also available for communication. So can anyone help how can i get solution for this.Meter pic are attach in attachment. M-Cubed 100 is Windows-based software for meter reading, and for configuring meters and modems manufactured by Secure. It helps utilities to improve their billing efficiency by eliminating the errors that arise from manual data punching. Meters can be read remotely, via a modem, or directly, using a meter reading instrument (MRI).

Here are the steps to read the meter.

1. Wait till the display is automatically switched on (don’t press any buttons)

2. After display reset,

1st reading – [tue 14.09.16] – Current date

2nd reading – [tm 07.30.55] – Current time

3rd reading – [U 000753.5 kWh ->] – Current import energy reading

4th reading – [U 0002.32 kVA ->] – Up to now, max import demand seen for this month (in kVA)

5th reading – [U d04.09.16 ->] – Date when the above max import demand occurred

6th reading – [U tm13.10.00 ->] – Time when the above max import demand occurred

7th reading – [U 000725.2 kWh ->] – Imported energy reading for the previous month (before meter reset)

350

8th reading – [U 0002.73 kVA ->] – Max imported demand for previous month

9th reading – [U d28.08.16 ->] – Date when the above max import demand occurred (previous month)

10th reading – [U tm04.23.00 ->] – Time when the above max import demand occurred (previous month)

Secure Sprint 350 Energy Meter User Manual

from 11th reading to 18th, same format follows for exported (generated) energy. Eg. 15th reading (same as 7th) will give you the Exported energy reading for the previous month.

Hope this gives some insight to what you need. Let me know if you have queries.

Secure Meters Sprint 350 User Manual

Harshana

Rate this project
0.0

Secure Meters Sprint 350 Manual

13933total visits,14visits today