Fluke 39 Power Meter User Manual
Fred Morris on Fluke 1750/B Power Quality Recorder Repair John Perry on Fluke 6241-14M Pressure Controller Repair Brad Scoville on Fluke 6241-7M Pressure Controller Repair. Fluke 39 Power Meter and 41B Power Harmonics Analyzer Product Home Features Specifications Models, Options & Accessories Manuals The Fluke 39 Power Meter and Fluke 41B Harmonics Analyzer combine the ease of use of a digital multimeter, the visual feedback of an oscilloscope and the power of a. Fluke 39 and 41B Power Meters Models. Fluke Corporation. Keeping your world up and running.® Leader in test and measurement software. Fluke Corporation is the world leader in professional electronic test tools and software for measuring and condition monitoring. Fluke tools are known for portability, safety, ease-of-use, accuracy and rigid standards of quality. Select your region.
- Fluke 87v Multimeter User Manual
- Fluke Fiber Power Meter
- Fluke Power Monitoring Meters
- Fluke 39 Power Meter Manual
- Atec Fluke-39-41B User Manual Features, Three views of each reading, Safety conformance. The Model 39 Power Meter and 41B Harmonics Analyzer combine the ease of. Use of a digital multimeter, the visual feedback of an oscilloscope and the. Power of a harmonics analyzer in a single instrument.
- Actions that pose hazards to the user. Electrical symbols used on the Meter and in this manual are explained in Table 1. XW Warning To avoid possible electric shock or personal injury, follow these guidelines. Power-up Disables automatic power-off feature (Meter normally powers off in 30 minutes). The Meter reads “PoFF” until A is.
- TRUE RMS CLAMP METER. The Clamp Meter of Choice for Adjustable Speed Drive Measurements, with True-rms Crest and Frequency Measurement. The Fluke 33 give accurate True-rms current measurements from 0.3 to 700A max. In addition, the Model 33 captures peak values, up to 1000A, for Crest Factor calculation.
- We hereby certify that the Fluke Model 45 Dual Display MultiMeter is in compliance with BMPT Vfg 243/1991 and is RFI suppressed. The normal operation of some equipment (e.g. Signal generators) may be subject to specific restrictions. Please observe the notices in the users manual.
®
Model 187 & 189
True RMS Multimeter
Users Manual
August 2000, Rev.2, 6/02
© 2000, 2002 Fluke Corporation. All rights reserved. Printed in U.S.A.
All product names are trademarks of their respective companies.
- Model 187 & 189 True RMS Multimeter
- 1. Before You Start
- 2. Getting Acquainted
- Battery Considerations
- Understanding the Display
- Using FAST MN MX
- 3. Making Measurements
- Measuring Voltage
- Measuring Current
- 4. Using Memory & Communications Features
- Types of Memory
- 5. Changing the Default Settings
- 6. Maintenance
- 7. Specifications
Features, Three views of each reading, Safety conformance
The Model 39 Power Meter and 41B
Harmonics Analyzer combine the ease of
use of a digital multimeter, the visual
feedback of an oscilloscope and the
power of a harmonics analyzer in a
single instrument. If you're testing power
on three-phase systems or trouble-
shooting harmonics on non-linear loads,
no test tool makes it easier.
The Model 41B is ideal for further
analyzing data and optimizing system
performance. Use the Model 41B'$
FlukeView
software (included) to
download acquired data to a printer or
an MS-DOS or Windows
compatible
computer for analysis and presentation.
Three Views of each reading:
• Waveform
• Bargraph showing harmonic levels
Numeric values
a Real-time display updates. Display
updates three times per second,
providing a dynamic view of actual
circuit conditions
Comprehensive measurements.
Measure rms, peak and total harmonic
distortion (THD( for complex voltages
and currents - with no manual
calculations required.
„a
Three-Phase readings
From a simple single-phase
measurement, automatically calculates
three-phase power and power factor
for three-wire balanced loads,
Fluke 87v Multimeter User Manual
System Critical Data Immediate
readings of Power Factors, KVAR,
Crest Factor, K-Factor
• Display Harmonics individually to
the 31 st
• Min/Max and Average recording
• Data Storage of up to eight complete
measurement sets (Fluke 41B)
*On-line Data Logging with connection to
Fluke Fiber Power Meter
laptop computer (Fluke 41B(
Safety Conformance
Independently tested and approved
for CSA C22.2 No. 1010-1, TUV to
EN61010 and UL3111 listing. Protected
to IEC 61010-1 Category III 600V
Features
Direct 30 power readouts from simple single-phase measurement
i
True-rms voltage from 5.OV to 600V
True-rms current from 1A to SODA (1000A with optional probe}
Peak, DC. and Crest Factor
Total harmonic distortion (%THDF and %THDR)
Active power from IOW to 3OOkW (6OOkW with optional probe}
Apparent power (VA) & Reactive Power (VAR)
Total Power factor (PF)
Displacement Power Factor (DPF)
K-factor
Frequency from 6Hz - 99.9Hz (fundamental)
Harmonics to 31st
Phase angle of fundamental and harmonics
Waveform, text and spectrum displays
Record mode - MIN. MAX and AVG
Zoom mode on harmonics bargraphs
46
0
Memory for 8 complete data sets
Data Logging
Optically isolated RS-232 interface
FfukeView PC software for Windows and DOS included